Part Number Hot Search : 
DSP16 MUR130G T1300 P6KE180 IDT6198L C2003 PKN030CA CR703A
Product Description
Full Text Search
 

To Download SM3000RMXL2UTAA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  taa-compliant smartpro 120v 3kva 2.88kw line-interactive sine wave ups, extended run, snmp, webcard, 2u, lcd, usb, db9 serial model number: SM3000RMXL2UTAA description tripp lite smartpro line interactive ups with enhanced lcd interface offers network-grade power protection for critical server, network and telecommunications equipment. line interactive uninterruptible power supply (ups) with built-in auto-voltage regulation (avr) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. tripp lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. interactive lcd/led interface reports ups operating mode, detailed ups and site-power data, plus enables a variety of ups setup and configuration options. super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 96% line-mode efficiency offers reduced heat emissions and operating costs. network management interfaces support communications via usb, rs-232 and optional snmpwebcard network interface. hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x. network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. includes poweralert monitoring software and complete cabling. switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. emergency power off (epo) interface. led/lcd display panel easily rotates for viewing in rackmount or tower configurations. audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. programmable self-test. field-replaceable, hot-swappable battery modules. features compliant with the federal trade agreements act (taa) for gsa schedule purchases tripp lite SM3000RMXL2UTAA line interactive 2u rack/tower ups with 3000va / 3kva capacity and extended runtime options line interactive ups with automatic voltage regulation (avr) corrects brownouts and overvoltages from 83 to 145v nema l5-30p input plug; 8 nema 5-15/20r and 1 l5-30r output receptacles, two independently switchable output load banks maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages highlights federal trade agreements act / taa compliant for gsa schedule purchases 3kva / 3000va / 2880w line interactive 2u rack/tower ups 120v nominal output during brownouts to 83v and overvoltages to 145v interactive lcd provides ups status information and advanced configuration options expandable runtime, hot-swap batteries, 96% efficiency, sine wave output usb, rs232 & epo ports, support for snmp/web card option nema l5-30p input; 8 nema 5-15/20r & 1 l5-30r outlets this product is energy star qualified for its ability to save customers money while helping to protect the environment applications ideal for server, networking and telecommunications equipment package includes SM3000RMXL2UTAA ups system poweralert software with usb, serial & epo cabling 4 post rackmount installation kit instruction manual 1 / 5
high 96% efficiency rating in line-power mode offers reduced power consumption and btu emisssions internal batteries offer 10 minutes at 50% load (1440w) and 3 minutes at 100% load (2880w) extended runtime is available with optional bp48v24-2u / bp48v242utaa (limit 1) or bp48v60rt3u / bp48v60rt3utaa (no limit) external battery configurations require the use of tripp lite's external battery configuration software (see manual) hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment front panel lcd monitoring screen with mode and enter buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed ups and site power information lcd interface also supports a number of advanced user setup and operating preferences ships with 4 post rackmount installation hardware; optional 2postrmkitwm enables 2 post rackmount/wallmount installation; optional 2-9ustand enables tower placement built-in usb, rs-232 and optional snmpwebcard accessory monitoring options hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x included poweralert ups monitoring software; built-in emergency power off (epo) interface with cable specifications output output volt amp capacity (va) 3000 output kva capacity (kva) 3 output watt capacity (watts) 2880 output kw capacity (kw) 2.88 power factor .96 nominal output voltage(s) supported 120v frequency compatibility 60 hz output voltage regulation (line mode) +6%, -14% output voltage regulation (battery mode) +/-5% output receptacles (8) 5-15/20r; (1) l5-30r load management receptacles two switchable single outlet 5-15/20r load banks output circuit breakers two 20a output breakers protect 4 5-15/20r outlets each output ac waveform (ac mode) pure sine wave output ac waveform (battery mode) pure sine wave input rated input current (maximum load) 24a nominal input voltage(s) supported 120v ac ups input connection type l5-30p 2 / 5
ups input cord length (ft.) 10 ups input cord length (m) 3 recommended electrical service 30a 120v input phase single-phase battery full load runtime (min.) 3 min. (2880w) half load runtime (min.) 10 min. (1440w) expandable battery runtime extended runtime supported via optional external battery packs external battery pack compatibility bp48v24-2u (limit 1); bp48v60rt-3u (multi-pack compatible); bp48v27-2us (multi-pack compatible) dc system voltage (vdc) 48 battery recharge rate (included batteries) less than 5 hours from 10 to 90% internal ups replacement battery cartridge rbc58-2u battery access front panel battery access door battery replacement description hot-swappable, replaceable batteries voltage regulation voltage regulation description automatic voltage regulation (avr) maintains line power operation with an input voltage range of 83 to 145 overvoltage correction input voltages between 127 and 145 are reduced by 12% undervoltage correction input voltages between 108 and 96 are boosted by 12% severe undervoltage correction input voltages between 83 and 95 are boosted by 24% user interface, alerts & controls front panel lcd display front panel lcd information and configuration screen offers detailed ups and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed lcd configuration and monitoring options) switches 3 pushbutton switches control off / on power status, mode selection and mute / enter control functions alarm cancel operation power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available audible alarm audible alarm indicates ups startup, power-failure, low-battery, overload, ups fault and remote shutdown conditions surge / noise suppression ups ac suppression joule rating 570 emi / rfi ac noise suppression yes ac suppression response time instantaneous physical 3 / 5
installation form factors supported with included accessories 4 post 19 inch rackmount installation form factors supported with optional accessories 2 post rackmount (2postrmkitwm); wallmount (2postrmkitwm); tower (2-9ustand) primary form factor rackmount ups power module dimensions (hwd, in.) 3.5 x 17.5 x 19 ups power module dimensions (hwd, cm) 8.9 x 44.4 x 48.3 rack height (u spaces) 2 ups power module weight (lbs.) 84.6 ups power module weight (kg) 38.4 ups shipping dimensions (hwd / in.) 9 x 23.5 x 20 ups shipping dimensions (hwd / cm) 22.9 x 59.7 x 50.8 shipping weight (lbs.) 84.6 shipping weight (kg) 38.4 cooling method fan ups housing material steel environmental operating temperature range +32 to +104 degrees fahrenheit / 0 to +40 degrees celsius storage temperature range +5 to +122 degrees fahrenheit / -15 to +50 degrees celsius relative humidity 0 to 95%, non-condensing ac mode btu / hr. (full load) 409 communications communications interface usb (hid enabled); db9 serial; epo (emergency power off); slot for snmp/web interface network monitoring port description supports detailed monitoring of ups and site power conditions poweralert software included communications cable usb, db9 and epo cabling included line / battery transfer transfer time 5 milliseconds (ac to battery mode), 1 millisecond (battery to ac mode) low voltage transfer to battery power (setpoint) 83 high voltage transfer to battery power (setpoint) 145 special features 4 / 5
cold start (startup in battery mode during a power failure) cold-start operation supported high availability ups features hot swappable batteries green energy-saving features greater than 95% efficiency - green ups; individually controllable load banks certifications ups certifications tested to ul1778 (usa); tested to csa (canada); tested to nom (mexico); meets fcc part 15 category a (emi); rohs (restriction of hazardous substances); taa compliant; energy star qualified warranty product warranty period (worldwide) 2-year limited warranty connected equipment insurance (u.s., canada & puerto rico) $250,000 ultimate lifetime insurance ? 2015 tripp lite. all rights reserved. all trademarks are the sole property of their respective owners. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. photos may differ slightly from final products. 5 / 5


▲Up To Search▲   

 
Price & Availability of SM3000RMXL2UTAA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X